Overview
Overview of Eaton BRN260GF 60 Amp 2-Pole 120/240V GFCI Circuit Breaker | New
The Eaton BRN260GF 60 Amp 2-Pole 120/240V GFCI Circuit Breaker merges branch-circuit overcurrent safety with ground-fault personal safety within a single unit. Engineered for compatible Eaton BR load centers, this dual-pole GFCI breaker has a 60 amp rating and operates at 120/240V AC, making it ideal for circuits built to demand both the necessary capacity and GFCI safety features. Its pigtail neutral design sets it apart from Eaton’s plug-on neutral versions. As a component of Eaton’s digital BR series two-pole GFCI platform, the BRN260GF employs microprocessor-based detection to differentiate between transient leakage situations and faults that necessitate interruption. The platform offers diagnostic trip-code alerts to assist certified electrical professionals in determining the reasons for tripping. This Eaton 60 amp GFCI breaker provides coordinated two-pole protection for suitable residential and light-commercial electrical setups, featuring a 10 kA interrupting rating and common-trip functionality.
Key Features of Eaton BRN260GF 60 Amp 2-Pole 120/240V GFCI Circuit Breaker
• 60 amp current rating: Provides the specified branch-circuit rating for properly selected loads, conductors, and compatible equipment.
• Two-pole, 120/240V AC design: Supports compatible two-pole electrical circuits within the breaker’s voltage rating.
• Ground-fault personnel protection: Uses approximately 5 mA ground-fault sensitivity to help protect people from electric-shock hazards.
• Pigtail neutral connection: Includes a neutral lead for the required connection in an approved, compatible installation.
• Common-trip operation: Trips both poles together when the breaker operates.
• 10 kA interrupting rating: Rated to interrupt up to 10,000 amps of available fault current under its specified conditions.
• Digital ground-fault detection: Uses microprocessor-based sensing to help distinguish temporary leakage conditions from faults requiring a trip.
• Diagnostic trip notifications: Eaton’s digital BR two-pole platform provides 12 diagnostic indications to assist with identifying trip conditions.
• Eaton BR load-center compatibility: Intended for approved applications in compatible BR equipment; verify the panel’s labeling before selection.
• Published terminal wire range: Eaton lists #14–4 AWG terminal acceptance. The permitted conductor size for a 60A circuit must be determined separately from applicable installation requirements.
• UL standards: Listed product documentation identifies UL 489 and UL 943.
Benefits of Eaton BRN260GF 60 Amp 2-Pole 120/240V GFCI Circuit Breaker
🗹 Combine protection functions in one breaker: Provides branch-circuit overcurrent protection and ground-fault personnel protection without relying solely on a separate GFCI receptacle.
🗹 Help reduce unwanted ground-fault trips: Digital sensing is designed to evaluate transient leakage while responding to conditions that require protective interruption.
🗹 Make troubleshooting more informative: Diagnostic indications help electrical professionals distinguish ground faults, overcurrent events, power-quality issues, and certain internal errors.
🗹 Disconnect both circuit poles together: Common-trip operation provides coordinated interruption for the protected two-pole circuit.
🗹 Support compatible BR system upgrades: The pigtail-neutral configuration provides an option for approved BR installations without requiring a plug-on neutral breaker configuration.
🗹 Address applicable GFCI requirements: Helps meet ground-fault protection requirements when correctly selected and installed for the circuit, equipment, and locally adopted electrical code.
Specifications
Specifications for Eaton BRN260GF 60 Amp 2-Pole 120/240V GFCI Circuit Breaker | New
| Manufacturer | Eaton |
| Manufacturer Part Number | BRN260GF |
| Product Name | Eaton BRN260GF 60 Amp 2-Pole 120/240V GFCI Circuit Breaker |
| Product Type | Ground-fault circuit interrupter circuit breaker |
| Published Type Designation | GFTCB |
| Protection Category | Ground-fault personnel protection |
| Rated Current | 60A |
| Number of Poles | Two |
| Rated Voltage | 120/240V AC |
| Interrupting Rating | 10 kAIC / 10,000A |
| Trip Configuration | Common trip |
| Neutral Connection | Pigtail neutral wire |
| Plug-On Neutral Configuration | No; the “N” in BRN260GF identifies the pigtail-neutral design |
| Ground-Fault Function Code | GF |
| Ground-Fault Trip Sensitivity | Nominal 5 mA for personnel protection |
| Equipment-Protection Classification | Not the EP/30 mA equipment-protection version |
| Overcurrent Protection | Circuit-breaker protection for overload and short-circuit conditions |
| Ground-Fault Detection Technology | Digital, microprocessor-based |
| Ground-Fault Response | Evaluates leakage conditions and responds in milliseconds |
| Transient-Leakage Handling | Designed to disregard transient conditions that could otherwise cause unwanted trips |
| Diagnostic Indication | Multicolor LED with blink-code notifications |
| Diagnostic Indications | 12 indications, including startup and mechanical-trip status |
| Published Terminal Wire Range | #14–4 AWG, as stated on Eaton’s exact-SKU page |
| Breaker Format | BR 1-inch-per-pole format |
| Panel Spaces | Two nominal 1-inch spaces |
| Overall Length | 2 inches / 50.8 mm |
| Overall Width | 3 inches / 76.2 mm |
| Overall Depth | 4.25 inches / approximately 108 mm |
| Platform Standards | UL 489, UL 943, UL 1053, and UL 1998; cUL is also listed |
| NEC Provisions | Eaton’s platform literature references 2020 and 2023 NEC updates to Sections 210.8 and 422.5 |
| Multiple colors, six blinks | Startup sequence |
| Yellow, two blinks | Digital command error |
| Yellow, three blinks | Microprocessor error |
| Yellow, four blinks | GFCI hardware error |
| Green, two blinks | Power-quality issue |
| Blue, two blinks | Overvoltage |
| Blue, three blinks | Overcurrent trip |
| White, two blinks | Grounded-neutral fault |
| White, three blinks | Low-level ground fault |
| White, four blinks | High-level ground fault |
| White, five blinks | Cold-start ground fault |
| No blink after startup | Mechanical trip, such as a short circuit |
User Guides
Frequently Asked Questions
Eaton BRN260GF 60 Amp 2-Pole 120/240V GFCI Circuit Breaker
Frequently Asked Questions (FAQ's)
What amperage is the Eaton BRN260GF rated for?
The BRN260GF has a 60-amp current rating.
What voltage does the BRN260GF support?
Eaton rates this breaker for 120/240V AC applications.
How many poles does the BRN260GF have?
It is a two-pole circuit breaker, designed to disconnect two ungrounded conductors together.
Does the BRN260GF provide GFCI protection?
Yes. Eaton identifies it as a ground-fault personnel protection circuit breaker with integrated GFCI functionality.
What does GFCI protection do?
GFCI protection monitors the current balance in the protected circuit and is designed to open the circuit when a qualifying ground-fault imbalance is detected.
Does this breaker have a common trip?
Yes. Eaton specifies a common-trip mechanism, so both poles operate together during a breaker trip.
Does the BRN260GF include a neutral pigtail?
Yes. The product is specifically identified as a pigtail-neutral GFCI breaker.
Where does the neutral pigtail connect?
In a supported installation, the breaker’s pigtail connects to the appropriate neutral bus according to Eaton’s installation instructions and applicable electrical code.
What is the interrupt rating?
The BRN260GF has a 10 kAIC interrupt rating, meaning it is rated for an interrupting capacity of 10,000 amperes under specified test and system conditions.
What wire sizes does the BRN260GF accept?
Eaton specifies a conductor range of #14 through #4 AWG. The correct conductor size for a particular 60A installation depends on conductor material, insulation rating, termination requirements, temperature ratings, and applicable electrical code.
Is the BRN260GF compatible with Eaton BR panels?
Yes. It is part of Eaton’s BR family and is intended for compatible BR-series distribution equipment. Exact load-center compatibility should still be confirmed before purchase.
Can it be used in a spa panel?
Eaton describes BR breakers as being used in compatible load centers, spa panels, meter breakers, and subpanels. The exact panel and application must still be approved for this breaker.
Is the BRN260GF UL listed or certified?
Eaton lists certifications to UL 943 and UL 489.
What is UL 943?
UL 943 is a safety standard associated with ground-fault circuit interrupters. Eaton lists BRN260GF as certified to this standard.
What is UL 489?
UL 489 is a standard covering molded-case circuit breakers and related circuit-protection equipment. The BRN260GF is also certified to this standard.
What are the dimensions of the breaker?
Eaton specifies approximately 4.25 inches long, 3 inches wide, and 2 inches high.
How much does the BRN260GF weigh?
Eaton lists the breaker at approximately 1 pound.
What is the UPC for the Eaton BRN260GF?
The manufacturer UPC is 786676043816.
Can this breaker replace any 60A two-pole breaker?
No. Matching amperage and pole count alone are not enough. The breaker must be specifically approved for the load center or panel, and the application must meet electrical-code, voltage, interrupt-rating, conductor, and GFCI requirements.
Who should install the Eaton BRN260GF?
Circuit-breaker work exposes installers to potentially lethal electrical energy. Installation should be completed by a qualified electrical professional who can verify panel compatibility, conductor sizing, torque requirements, grounding and neutral arrangements, available fault current, and applicable electrical codes.